BAM trì ìrean Àrd bholtaids Cumhachd Capacitor

Tuairisgeul goirid:

Àirde: nas lugha na 1000m; Ambient Teòthachd: -40 ℃ ~ +40 ℃.
Gun crathadh meacanaigeach brùideil, gun gas is bhalbhaichean cronail, gun dealan, agus duslach spreadhaidh agus spreadhaidh na àite.
Bholtaids obrachaidh leantainneach: 1.00 Un, max fad-ùine, Thar bholtaids: less.1 Un.
Over-curent seasmhach (a’ toirt a-steach harmonics sruth) nas lugha 1.3 In.

Mion-fhiosrachadh toraidh

Bathar Tags

Capacitor cumhachd àrd bholtachd BAM

Iarrtas agus Inbhean:

Tha capacitor bholtachd àrd air a chleachdadh sa mhòr-chuid anns an t-siostam AC Power le 50Hz gus factar cumhachd a leasachadh. Tha an coileanadh a’ nochdadh gu GB 3083.2-89 《High bholtaids shunt capacitor》 agus IEC60871-1987.

GB/T11024-2010 Inbhe nàiseanta 《Boltaids ìre 1kV no nas àirde na capacitors shunt airson siostaman cumhachd AC

JB / 7112-2000 Inbhe gnìomhachas innealan 《HV Shunt Capacitor cruinnichte

DL/T628-1997 Inbhe Gnìomhachas Cumhachd Dealain 《Riatanas Teicnigeach òrdachadh HV Shunt Capacitor ag òrdachadh》

Riatanasan cleachdaidh:

1.Altitude: nas lugha na 1000m; Ambient Teòthachd: -40 ℃ ~ +40 ℃.

2. Gun chrathadh meacanaigeach fòirneartach, gun ghas is bhalbhaichean cronail, gun dealan, agus spreadhadh, agus duslach spreadhaidh san àite.

3.Continuous obrachadh bholtaids: 1.00 Un, fad-ùine max, Thar bholtaids: less.1 Un.

4.Stable over-curent (a 'gabhail a-steach gnàthach harmonics) nas lugha 1.3 In.

5.With seasamh bholtaids: eadar terminal 2.15, bholtaids ìre ùine airson 10 diogan, eadar cinn-uidhe agus container 42kV airson 10 diogan.

Prìomh fheartan teicnigeach:

1.Rated bholtaids: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11 / √3kV, feuch an cuir thu fios san òrdugh ma tha thu ag iarraidh an comas sònraichte eile.

2.Rated comas: 33 ~ 334kvar cuir an cèill san òrdugh ma tha thu ag iarraidh an comas sònraichte eile.

3.Capacity tolerance: -5 ~ 15%.

4.Loss aingeal luach buailteach: film & pàipear meadhanach tg θ≦0.08%, film meadhan tg θ≦0.05%.

5.Withstand bholtaids: faodaidh e cothrom a thoirt do AC2.15 no DC4.3 amannan bholtaids rangachadh eadar na pales comas, mu dheireadh mu 10sg gun bhriseadh no flash, BIL: 6kV(30kV), 10kV(42Kv).

Sgaoileadh 6.Free: tha an aghaidh a-staigh aige, 10min às deidh an solar cumhachd a ghearradh dheth, lughdaichidh am bholtadh fuigheall gu 75V bho √2 Un.

7.Max. An-dràsta: a 'ruith gu rèidh fon bholtadh ìre 1.3 ùine, thar bholtaids, comas fulangas dearbhach agus tonn harmonic nach urrainn a bhith nas fhaide na 1 min gach 24 uair.

8.Max.Current: a 'ruith gu rèidh fon bholtaids ìre 1.3 ùine, thar bholtaids, comas fulangas dearbhach agus tonn harmonic nach urrainn sruth 1.43 ùine a mheasadh.

9.Standard: GB/T 112024.1-2001, IEC6087:1997.

tr

CAPACITOR CUMHACHD EILEANACH ÌRE

Modail
BAM
Ìre Voltage
(kV)
Toradh Rangaichte (kVAr) Ìre comas (uF) Ìre gnàthaichte ann an(A)
6.3-25-1W 6.3 25 2.006 3. 968
6.3-30-1W 6.3 30 2.406 4.762
6.6 / √3-25-1W 6.6/√3 25 5.481 6.561
6.3/√3-30-1W 6.6/√3 30 6.577 7.873
6.3/√3-50-1W 6.6/√3 50 10.96 13.12
10.5-25-1W 10.5 25 0.722 2.38
10.5-30-1W 10.5 30 0.886 2.857
10.5-50-1W 10.5 50 1.444 4.762
11/√3-30-1W 11/√3 30 2. 368 4.724
11/√3-50-1W 11/√3 50 3. 946 7.873
6.3-30-1W 6.3 30 2.4 4.76
6.3-50-1W 6.3 50 4 7.9
6.3-100-1W 6.3 100 8 15.9
6.3-200-1W 6.3 200 16 31.7
6.3-300-1W 6.3 300 fichead 's a ceithir 47.6
6.3-334-1W 6.3 334 26.8 53
10.5-50-1W 10.5 50 1.44 4.8
10.5-100-1W 10.5 100 2.9 9.5
10.5-150-1W 10.5 150 4.3 14.3
10.5-200-1W 10.5 200 5.8 19
10.5-300-1W 10.5 300 8.67 28.6
10.5-334-1W 10.5 334 9.65 31.8
11/√3-50-1W 11/√3 50 3.95 7.87
11/√3-100-1W 11/√3 100 7.89 15.75
11/√3-150-1W 11/√3 150 11.84 23.6
11/√3-200-1W 11/√3 200 15.78 31.5
11/√3-300-1W 11/√3 300 23.68 47.2
11/√3-334-1W 11/√3 334 26.36 52.6
6.6 / √3-50-1W 6.6/√3 50 10.96 13.12
6.6 / √3-100-1W 6.6/√3 100 21.9 26.24
6.6 / √3-150-1W 6.6/√3 150 32.9 39.36
6.6 / √3-200-1W 6.6/√3 200 43.8 52.48
6.6 / √3-300-1W 6.6/√3 300 65.8 78.7
6.6 / √3-334-1W 6.6/√3 334 73.2 87.6
11-100-1W 11 100 2.63 9.1
11-150-1W 11 150 3.95 13.6
11-200-1W 11 200 5.26 18.2
11-300-1W 11 300 7.89 27.3
11-334-1W 11 334 8.79 30.4
12-100-1W 12 100 2.2 8.33
12-150-1W 12 150 3.3 12.5
12-200-1W 12 200 4.4 16.7
12-300-1W 12 300 6.64 25
12-334-1W 12 334 7.39 27.8
12/√3-100-1W 12/√3 100 6.63 14.4
12/√3-150-1W 12/√3 150 9.95 21.7
12/√3-200-1W 12/√3 200 13.3 28.9
12/√3-300-1W 12/√3 300 19.9 43.3
12/√3-334-1W 12/√3 334 22.1 48.2
12/√3-400-1W 12/√3 400 26.54 57.74
6.3-100-1W 6.3 100 8 15.9
6.3-150-1W 6.3 150 12 23.8
6.3-200-1W 6.3 200 16 31.7
6.3-300-1W 6.3 300 fichead 's a ceithir 47.6
6.3-334-1W 6.3 334 26.8 53
6.6-100-1W 6.6 100 7.3 15.2
6.6-150-1W 6.6 150 11 22.7
6.6-200-1W 6.6 200 14.6 30.3
6.6-300-1W 6.6 300 fichead 's a dhà 45.5
6.6-334-1W 6.6 334 24.4 50.6
6.6 / √3-100-1W 6.6/√3 100 21.9 26.24
6.6 / √3-150-1W 6.6/√3 150 32.9 39.36
6.6 / √3-200-1W 6.6/√3 200 43.8 52.48
6.6 / √3-300-1W 6.6/√3 300 65.8 78.7
6.6 / √3-334-1W 6.6/√3 334 73.2 87.6
11/√3-100-1W 11/√3 100 7.89 15.75
11/√3-150-1W 11/√3 150 11.84 23.6
11/√3-200-1W 11/√3 200 15.78 31.5
11/√3-300-1W 11/√3 300 23.68 47.2
11/√3-334-1W 11/√3 334 26.36 52.6
11-100-1W 11 100 2.63 5.25
11-150-1W 11 150 3.95 7.87
11-200-1W 11 200 5.26 10.5
11-300-1W 11 300 7.9 15.75
11-100-1W 11 100 2.63 5.25
11-150-1W 11 150 3.95 7.87
11-200-1W 11 200 5.26 10.5
11-300-1W 11 300 7.9 15.75
12-100-1W 12 100 2.2 4.8
12-150-1W 12 150 3.3 7.2
12-200-1W 12 200 4.4 9.6
12-300-1W 12 300 6.64 14.45
12-100-1W 12 100 2.2 4.8
12-150-1W 12 150 3.2 7.2
12-200-1W 12 200 4.4 9.6
12-300-1W 12 300 6.64 14.45
11/√3-200-1W 11/√3 200 15.78 31.5
11/√3-334-1W 11/√3 334 26.36 52.6
12/√3-200-1W 12/√3 200 13.3 28.9
12/√3-334-1W 12/√3 334 22.1 48.2
12-200-1W 12 200 4.4 16.7
12-334-1W 12 334 7.39 27.8
10.5-200-1W 10.5 200 5.8 19
10.5-334-1W 10.5 334 9.65 31.8

  • Roimhe:
  • Air adhart: